With regard to environmental protection and conservation of resources, wastewater collection and transport play an important role. Continuous challenges, such as the increasing solid content in sewage, which hinders operating conditions for systems, require new and innovative solutions to constantly improve the processes and the corresponding products.

Wilo-Drain LP
Drain LP

Design

Self-priming drainage pump with standard motor for dry well installation

Application

Pumping of wastewater for

  • Ponds
  • Sprinkling / spraying of gardens and green areas
  • Mobile drainage

Special features / product benefits

Pumping of

  • Wastewater
  • Process water

Technical data

  • Mains connection: 1~230 V, 50 Hz
  • Protection class: 44
  • Fluid temperature: 3 ‐ 35 °C
  • Free ball passage: 5 mm
  • Connection: Rp 1½
  • Max. suction head: 6 m
Wilo-Drain STS 40
Drain STS 40

Design

Submersible sewage pump for intermittent operation for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1 or S3 25%
  • Protection class: IP 68
  • Insulation class: B
  • Thermal winding monitoring
  • Max. fluid temperature: 3 ‐ 35 °C
  • Cable length: 10 m
  • Free ball passage: 40 mm
  • Max. immersion depth: 5 m
Wilo-Drain TC 40
Drain TC 40

Design

Submersible sewage pump for intermittent operation for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz
  • Immersed operating mode: S1 or S3 25%
  • Surfaced operating mode: S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Thermal winding monitoring
  • Max. fluid temperature: 3 ‐ 40 °C
  • Cable length: 5 m
  • Free ball passage: 40 mm
  • Max. immersion depth: 5 m
Wilo-Drain TM/TMW/TMR 32
Drain TM/TMW/TMR 32

Design

Submersible drainage pump

Application

  • For pumping clear or slightly muddy water

    • From tanks, sumps or pits
    • For overflows and flooding
    • For draining basement stairways and basement areas

 

TMR

The TMR is suited for lowering the water level to a remaining level of 2 mm.

TMW

The service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by settling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours.

Wilo-Drain TMW 32 has a turbulator that prevents the build-up of sediment, expelling it together with the fluid. This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occupational safety hygiene regulations during cleaning of the pump sump are minimized.

Special features / product benefits

Pumping of

  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection 1~230 V, 50 Hz
  • Protection class: IP 68
  • Submersion depth max. 3 m
  • Fluid temperature 3 ‐ 35 °C, max. 90 °C for short periods up to 3 min.
  • Cable length 3 to 10 m, depending on type
  • Free ball passage 10 mm (TMR: 2 mm)
  • Pressure port Rp 1 ¼
Wilo-Drain TS 40-65
Drain TS 40-65

Design

Submersible drainage pump

Application

Pumping of

  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Protection class: IP 68
  • Max. immersion depth:TS 40 = 5 m; TS 50/TS 65 = 10 m
  • Fluid temperature: 3 ‐ 35 °C
  • Cable length: 10 m
  • Free ball passage: 10 mm
  • Pressure port: TS 40 = Rp 1, TS 50 = Rp 1¼, TS 65 = Rp 2½
Wilo-Drain TS/TSW 32
Drain TS/TSW 32

Design

Submersible drainage pump

Application

  • For pumping clear or slightly muddy water

    • From tanks, sumps or pits
    • For overflows and flooding
    • For draining basement stairways and basement areas

  • From domestic areas (washing machine water, soapsuds)
  • From small fountains, waterworks or streams

 

TSW

The service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by settling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours.

Wilo-Drain TSW 32 has a turbulator that prevents the build-up of sediment, expelling it together with the fluid. This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occupational safety hygiene regulations during cleaning of the pump sump are minimised.

Special features / product benefits

Pumping of

  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection 1~230 V, 50 Hz
  • Protection class IP 68
  • Max. immersion depth 10 m
  • Fluid temperature 3 - 35 °C, for short periods up to 3 min. max. 90 °C
  • Cable length 10 m
  • Free ball passage 10 mm
  • Rp 1 ¼ pressure port, hose connection Ø 32 mm, R1
Wilo-DrainLift Box
DrainLift Box

Design

Small sewage lifting unit for concealed floor installation

Application

For concealed floor installation, can be used to drain

  • Rooms subject to possible flooding
  • Garage entrances
  • Basement stairways
  • Showers, washbasins, washing machines, dishwashers

Special features / product benefits

Pumping of pre-cleaned sewage without faeces (according to DIN EN 12050-2) that cannot be piped to the sewer system through the use of natural falls.

Technical data

  • Mains connection 1~230 V, 50 Hz
  • Mains connection cable 10 m (5 m with 40/10), with shock-proof plug
  • Operating mode S3 -25%
  • Fluid temperature max. 35 °C, with 32/8 and 32/11 for short periods (3 min) 90 °C
  • Pressure port Ø 40 mm
  • Inlet connection 100 mm
  • Ventilation connection 100 mm
  • Protection class IP 67
  • Gross tank volume 85 l
  • Switching volume 22 l, 30 l with 40/10
Wilo-DrainLift M
DrainLift M

Design

Sewage lifting unit as single pump system or double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit that has the same performance capacity and switches on automatically when needed (DIN EN 12050‐1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Power consumption P1 = 1.3 kW
  • Cable length from system to switchgear 4 m / plug cable 1.5 m
  • Operating mode S3-15%, 80 sec
  • Fluid temperature max. 40 °C, for short periods (3 min.) 60 °C
  • Max. ambient temperature of 40 °C
  • Free ball passage 45 mm
  • Pressure port DN 80
  • Inlet connection DN 40 / DN 100 / DN 150
  • Ventilation connection DN 70
  • Min. suction head (installation level to middle of inlet) 180 mm
  • Protection class (without switchgear) IP 67
  • Gross tank volume 62 l to 115 l, depending on type
  • Switching volume 24 l to 40 l, depending on type
Wilo-DrainLift S
DrainLift S

Design

Compact sewage lifting unit as single pump system

Application

Complete sewage lifting unit ready for connection in accordance with DIN EN 12050-1.

For the pumping of raw sewage that cannot be piped to the sewer system through the use of natural inclines. Wilo-DrainLift S meets the requirements of DIN EN 12050-1 and DIN EN 12056. Minimum dimensions, combined with space-optimised installation area enable a wide range of different application options for:

  • Retrofitting installation of showers, toilets, saunas, etc.
  • Installation of toilets in basement flats
  • Expansion/renovation of flats and buildings
  • Innovative combination of different installation options for sewage lifting units in a single system, e.g.:

    • Direct toilet connection
    • Drainage of individual rooms
    • Front wall installation/recessed wall installation

Can be used in the following installation types:

As conventional sewage lifting unit for connection of a wall-mounted or stand-alone toilet or for complete room drainage. Due to compact design, system requires only minimum space.
In conjunction with front wall installation/recessed wall installation, used as sewage lifting unit, integrated into commercially available front wall installation systems, in recessed wall installation as well as in pedestal profiles.

Note:

It must be possible to both install and remove the system after laying tiles. Observe installation instructions and accessories.

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Power consumption P1 from 1.1 to 1.25 kW, depending on type
  • Cable length from system to switchgear/plug 4 m
  • Operating mode S3-15%, 120 sec
  • Fluid temperature max. 35 °C, for short periods up to 60 °C
  • Max. ambient temperature of 40 °C
  • Free ball passage 40 mm
  • Pressure port DN 80
  • Inlet connection DN 40 / DN 100
  • Ventilation connection DN 70
  • Min. suction head (installation level to middle of inlet) 180 mm
  • Protection class (without switchgear) IP 67
  • Gross tank volume 45 l
Wilo-DrainLift WS 40 Basic
DrainLift WS 40 Basic

Design

Pump chamber made of plastic with integrated pump as concealed pumping station or floor-mounted lifting unit

Application

Wilo-DrainLift WS 40 Basic is an automatically operating wastewater lifting unit in accordance with EN 12050-2 for backup-free drainage of sewage that does not contain faeces and that originates from building discharge points below the backflow level. The system can be installed in buildings as well as outside buildings in the same way as a plastic sump in the ground. The system is ideally suited for applications that involve seasonal wastewater (such as at camping sites, weekend homes, etc.) or in regions where the ground does not freeze to very deep levels.

Built-in pump

TC 40

For severely contaminated fluids; 40 mm free ball passage

Special features / product benefits

Pumping of pre-cleaned sewage without faeces that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level.

Technical data

Wilo-HiDrainlift 3
HiDrainlift 3

Design

Small sewage lifting unit for floor-mounted installation

Application

Pumping of pre-cleaned sewage without faeces (according to DIN EN 12050-2) that cannot be piped to the sewer system through the use of natural falls.

Special features / product benefits

Pumping of pre-cleaned sewage without faeces (according to DIN EN 12050-2) that cannot be piped to the sewer system through the use of natural falls.

Technical data

  • Netzanschluss 1~230 V, 50 Hz
  • Netzanschlusskabel 1,5 m, mit Schuko-Stecker (außer HiDrainlift 3-24)
  • Fördermedientemperatur max. 35 °C (bis zu 60/ 75 °C im Kurzzeitbetrieb für 5 Minuten, modellabhängig)
  • Druckanschluss DN 32
  • Zulaufanschluss DN 40
  • Schutzart IP 44
  • Behälter-Bruttovolumen 3,9 l / 16 l / 15,5 l
  • Schaltvolumen 1,7 l / 2 l / 2 l
Wilo-HiSewlift 3
HiSewlift 3

Design

Small sewage lifting unit with macerator

Application

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be piped to the sewer system through the use of natural falls.

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be piped to the sewer system through the use of natural falls.

Technical data

  • Netzanschluss 1~230 V, 50 Hz
  • Netzanschlusskabel 1,5 m, mit Schuko-Stecker
  • Fördermedientemperatur max. 35 °C
  • Druckanschluss DN 32
  • Zulaufanschluss DN 40
  • Schutzart IP 44
  • Behälter-Bruttovolumen 14,4 l / 17,4 l / 17,4 l
  • Schaltvolumen 1 l
Wilo-Drain MTC
Drain MTC

Design

Submersible sewage pump with external macerator for continuous duty for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz (only MTC 40) and 3~400 V, 50 Hz
  • Submerged operating mode: S1
  • Non-immersed operating mode: S2‑15 min or S3 30%
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3…40 °C (MTC 40: 3…35 °C)
  • Max. submersion depth: 10 m or 20 m
  • Cable length: 10 m
Wilo-Drain MTS
Drain MTS

Design

Submersible sewage pump with internal macerator for intermittent operation for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Submerged operating mode: S1
  • Non-immersed operating mode: S2-8 min; S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3…40 °C
  • Max. submersion depth: 10 m
  • Cable length: 10 m
Wilo-Drain STS 40
Drain STS 40

Design

Submersible sewage pump for intermittent operation for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1 or S3 25%
  • Protection class: IP 68
  • Insulation class: B
  • Thermal winding monitoring
  • Max. fluid temperature: 3 ‐ 35 °C
  • Cable length: 10 m
  • Free ball passage: 40 mm
  • Max. immersion depth: 5 m
Wilo-Drain TC 40
Drain TC 40

Design

Submersible sewage pump for intermittent operation for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz
  • Immersed operating mode: S1 or S3 25%
  • Surfaced operating mode: S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Thermal winding monitoring
  • Max. fluid temperature: 3 ‐ 40 °C
  • Cable length: 5 m
  • Free ball passage: 40 mm
  • Max. immersion depth: 5 m
Wilo-Drain TMT/TMC
Drain TMT/TMC

Design

Submersible drainage pump

Application

For industrial use, e.g. for condensate, hot water and aggressive fluids.

Special features / product benefits

Pumping of

  • Wastewater
  • Industrial wastewater with a maximum fluid temperature of 95 °C.

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Protection class: IP 68
  • Max. immersion depth: TMT 32: 7 m; TMC 32: 5 m; TMC 40: 5 m
  • Fluid temperature: immersed = 3 - 95 °C
  • Cable length: 10 m
  • Free ball passage: 9 mm
  • Pressure port: TMT 32…: G 1¼; TMC 32…: Rp 1¼; TMC 40: Rp 1½
Wilo-Drain TP 50/TP 65
Drain TP 50/TP 65

Design

Submersible sewage pump for continuous duty for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Non-immersed operating mode: S2-8 min, S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Thermal winding monitoring
  • Max. fluid temperature: 3 ‐ 35°C
  • Cable length: 10 m
  • Free ball passage: 44 mm
  • Max. immersion depth: 10 m
Wilo-Drain TP 80/TP 100
Drain TP 80/TP 100

Design

Submersible sewage pump for continuous duty for stationary and portable wet well installation, as well as stationary dry well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed and non-immersed operating modes: S1
  • Protection class: IP 68
  • Insulation class: F
  • Max. fluid temperature: 3 ‐ 40°C
  • Free ball passage: 80 or 95 mm
  • Max. immersion depth: 20 m
Wilo-DrainLift WS 40-50
DrainLift WS 40-50

Design

Pump chamber made of plastic as concealed pumping station or floor-mounted lifting unit

Application

Wilo-DrainLift WS 40-50 is an automatically operating sewage lifting unit in accordance with EN 12050 for backup-free drainage of sewage that either contains faeces or contains no faeces (depending on the type) and that originates from building discharge points below the backflow level.

The system can be installed in buildings as well as outside buildings in the same way as a plastic sump in the ground. The system is ideally suited for applications that involve seasonal wastewater (such as at camping sites, weekend homes, etc.), for use in regions where the earth does not freeze to very deep levels or also for use with pressure drainage.

When the system is used as a macerator lifting unit in a building, small pipeline diameters DN 40 and larger can be used on the pressure side in conformity with the relevant standard (in accordance with DIN EN 12050‐1). This enables flexible and low-cost overall installation.

Pumps that can be used

TP 50/TP 65

  • For severely contaminated fluids without faeces
  • 44 mm free ball passage
  • Ex-rated in accordance with ATEX (TP 65, depending on type)
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

 

MTS 40

  • For severely contaminated fluids and faeces
  • Patented, internal macerator
  • Single-phase and three-phase AC versions available
  • Three-phase version with Ex-rating in accordance with ATEX
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

Special features / product benefits

Pumping of fluids that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level:

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

Wilo-DrainLift WS 900/1100
DrainLift WS 900/1100

Design

Plastic pump chamber for insertion into the ground

Application

The Wilo-DrainLift WS 900/1100 is a single/double pump sump for pumping wastewater and sewage in building services out of rooms and from areas underneath the backflow level (EN 752). Suitable as a ready for connection pumps station for pressure drainage and as a pumping station for dewatering. The WS 900/1100 is installed in the ground outside the building. A time-saving, easy-to-install, low-cost solution for all consultants and building contractors.

Pump types that can be used

TS 40

  • For lightly contaminated fluids without faeces
  • 10 mm free ball passage
  • Not Ex-rated
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable

 

TP 50/TP 65

  • For severely contaminated fluids without faeces
  • 44 mm free ball passage
  • Ex-rated in accordance with ATEX (TP 65, depending on type)
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

Rexa FIT V05/V06

  • For severely contaminated fluids and faeces
  • 50 or 65 mm free ball passage
  • Not Ex-rated
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

Rexa PRO V05/V06

  • For severely contaminated fluids and faeces
  • 50 or 65 mm free ball passage
  • Ex-rated in accordance with ATEX as standard
  • Single-phase and three-phase AC versions available
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

TP 80

  • For severely contaminated fluids and faeces
  • 80 mm free ball passage
  • Ex-rated in accordance with ATEX as standard
  • Three-phase motor
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1
  • Can only be used for single pumping stations!

 

MTC 32

  • For severely contaminated fluids and faeces
  • External macerator
  • With and without Ex-rating in accordance with ATEX
  • For delivery heads up to 50 m
  • Compliant with (DIN) EN 12050-1

 

MTS 40

  • For severely contaminated fluids and faeces
  • Patented, internal macerator
  • Single-phase and three-phase AC versions available
  • Three-phase version with Ex-rating in accordance with ATEX
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

Special features / product benefits

Pumping of fluids that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level:

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

Wilo-DrainLift XL
DrainLift XL

Design

Sewage lifting unit as double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit that has the same performance capacity and switches on automatically when needed (DIN EN 12050-1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Power consumption P1 from 3 to 5.3 kW, depending on type
  • Cable length from system to switchgear 4 m / plug cable 1.5 m
  • Operating mode S1 / S3 ‐ 60%
  • Fluid temperature max. 40 °C, for short periods up to 60 °C
  • Ambient temperature max. 40 °C
  • Free ball passage 40 mm
  • Pressure port DN 80
  • Inlet connection DN 100 / DN 150
  • Ventilation connection DN 70
  • Min. suction head (installation level to middle of inlet) 700 mm
  • Protection class (without switchgear) IP 67
  • Gross tank volume 380 l
  • Switching volume 260 l
Wilo-DrainLift XXL
DrainLift XXL

Design

Sewage lifting unit as double-pump system with two separate dry-mounted pumps

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through sand catchers.

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Power consumption P1 from 2.3 to 10.0 kW, depending on type
  • Cable length from system to switchgear 10 m
  • Operating mode S1, S3
  • Fluid temperature max. 40 °C, for short periods up to 65 °C
  • Ambient temperature max. 40 °C
  • Free ball passage 78 mm to 95 mm, depending on type
  • Pressure port DN 80 or DN 100, depending on type
  • Inlet connection 3 x DN 100/150, 1 x DN 100
  • Ventilation connection DN 70 mm
  • Min. suction head (installation level to middle of inlet) 700 mm
  • Protection class (without switchgear) IP 68
  • Gross tank volume 400/800 l
  • Switching volume 200/400 l
Wilo-EMU FA (standard variant)
EMU FA (standard variant)

Design

Submersible sewage pump without cooling system for continuous duty for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Surfaced operating mode: S1, S2-15 or S2-30 (depending on type)
  • Thermal motor monitoring
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3 ‐ 40 °C
  • Cable length: 10 m
  • Free ball passage from 45 mm to 100 mm
  • Permanently lubricated roller bearings
  • Max. immersion depth: 20 m
Wilo-Rexa CUT
Rexa CUT

Design

Submersible sewage pump with macerator for intermittent duty and continuous duty, for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Non-immersed operating mode: S2-15 min/S2-30 min; S3 10%/S3 25% (motor-dependent)
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3…40 °C, max. 60 °C for 3 min
  • Max. immersion depth: 20 m
  • Cable length: 10 m
Wilo-RexaLift FIT L
RexaLift FIT L

Design

Sewage lifting unit as single pump system or double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit (RexaLift FIT L2) that has the same performance capacity and switches on automatically when needed (DIN EN 12050-1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Power consumption P1: 2.3 … 3.9 kW
  • Cable length from system to switchgear/plug: 4/1.5 m
  • Operating mode: S3-10%, 120 s
  • Fluid temperature: 3 °C … 40 °C, for short periods: 60 °C for max. 3 min.
  • Ambient temperature: 3 °C … 40 °C
  • Gross tank volume:
    • Single-pump system: 115 l
    • Double-pump system: 140 l

  • Switching volume:
    • Single-pump system: 35 l
    • Double-pump system: 50 l

  • discharge port: DN 80
  • Inlet connections: DN 50/DN 100/DN 150
  • Ventilation connection: DN 70
  • Free ball passage: 40 mm
  • Min. suction head (installation level to middle of inlet): 180 mm
  • Lifting unit protection class: IP67
  • Switchgear protection class: IP54
Wilo-Drain TMT/TMC
Drain TMT/TMC

Design

Submersible drainage pump

Application

For industrial use, e.g. for condensate, hot water and aggressive fluids.

Special features / product benefits

Pumping of

  • Wastewater
  • Industrial wastewater with a maximum fluid temperature of 95 °C.

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Protection class: IP 68
  • Max. immersion depth: TMT 32: 7 m; TMC 32: 5 m; TMC 40: 5 m
  • Fluid temperature: immersed = 3 - 95 °C
  • Cable length: 10 m
  • Free ball passage: 9 mm
  • Pressure port: TMT 32…: G 1¼; TMC 32…: Rp 1¼; TMC 40: Rp 1½
Wilo-Drain TP 80/TP 100
Drain TP 80/TP 100

Design

Submersible sewage pump for continuous duty for stationary and portable wet well installation, as well as stationary dry well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed and non-immersed operating modes: S1
  • Protection class: IP 68
  • Insulation class: F
  • Max. fluid temperature: 3 ‐ 40°C
  • Free ball passage: 80 or 95 mm
  • Max. immersion depth: 20 m
Wilo-DrainLift M
DrainLift M

Design

Sewage lifting unit as single pump system or double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit that has the same performance capacity and switches on automatically when needed (DIN EN 12050‐1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Power consumption P1 = 1.3 kW
  • Cable length from system to switchgear 4 m / plug cable 1.5 m
  • Operating mode S3-15%, 80 sec
  • Fluid temperature max. 40 °C, for short periods (3 min.) 60 °C
  • Max. ambient temperature of 40 °C
  • Free ball passage 45 mm
  • Pressure port DN 80
  • Inlet connection DN 40 / DN 100 / DN 150
  • Ventilation connection DN 70
  • Min. suction head (installation level to middle of inlet) 180 mm
  • Protection class (without switchgear) IP 67
  • Gross tank volume 62 l to 115 l, depending on type
  • Switching volume 24 l to 40 l, depending on type
Wilo-DrainLift WS 40 Basic
DrainLift WS 40 Basic

Design

Pump chamber made of plastic with integrated pump as concealed pumping station or floor-mounted lifting unit

Application

Wilo-DrainLift WS 40 Basic is an automatically operating wastewater lifting unit in accordance with EN 12050-2 for backup-free drainage of sewage that does not contain faeces and that originates from building discharge points below the backflow level. The system can be installed in buildings as well as outside buildings in the same way as a plastic sump in the ground. The system is ideally suited for applications that involve seasonal wastewater (such as at camping sites, weekend homes, etc.) or in regions where the ground does not freeze to very deep levels.

Built-in pump

TC 40

For severely contaminated fluids; 40 mm free ball passage

Special features / product benefits

Pumping of pre-cleaned sewage without faeces that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level.

Technical data

Wilo-DrainLift WS 40-50
DrainLift WS 40-50

Design

Pump chamber made of plastic as concealed pumping station or floor-mounted lifting unit

Application

Wilo-DrainLift WS 40-50 is an automatically operating sewage lifting unit in accordance with EN 12050 for backup-free drainage of sewage that either contains faeces or contains no faeces (depending on the type) and that originates from building discharge points below the backflow level.

The system can be installed in buildings as well as outside buildings in the same way as a plastic sump in the ground. The system is ideally suited for applications that involve seasonal wastewater (such as at camping sites, weekend homes, etc.), for use in regions where the earth does not freeze to very deep levels or also for use with pressure drainage.

When the system is used as a macerator lifting unit in a building, small pipeline diameters DN 40 and larger can be used on the pressure side in conformity with the relevant standard (in accordance with DIN EN 12050‐1). This enables flexible and low-cost overall installation.

Pumps that can be used

TP 50/TP 65

  • For severely contaminated fluids without faeces
  • 44 mm free ball passage
  • Ex-rated in accordance with ATEX (TP 65, depending on type)
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

 

MTS 40

  • For severely contaminated fluids and faeces
  • Patented, internal macerator
  • Single-phase and three-phase AC versions available
  • Three-phase version with Ex-rating in accordance with ATEX
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

Special features / product benefits

Pumping of fluids that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level:

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

Wilo-DrainLift WS 900/1100
DrainLift WS 900/1100

Design

Plastic pump chamber for insertion into the ground

Application

The Wilo-DrainLift WS 900/1100 is a single/double pump sump for pumping wastewater and sewage in building services out of rooms and from areas underneath the backflow level (EN 752). Suitable as a ready for connection pumps station for pressure drainage and as a pumping station for dewatering. The WS 900/1100 is installed in the ground outside the building. A time-saving, easy-to-install, low-cost solution for all consultants and building contractors.

Pump types that can be used

TS 40

  • For lightly contaminated fluids without faeces
  • 10 mm free ball passage
  • Not Ex-rated
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable

 

TP 50/TP 65

  • For severely contaminated fluids without faeces
  • 44 mm free ball passage
  • Ex-rated in accordance with ATEX (TP 65, depending on type)
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

Rexa FIT V05/V06

  • For severely contaminated fluids and faeces
  • 50 or 65 mm free ball passage
  • Not Ex-rated
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

Rexa PRO V05/V06

  • For severely contaminated fluids and faeces
  • 50 or 65 mm free ball passage
  • Ex-rated in accordance with ATEX as standard
  • Single-phase and three-phase AC versions available
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

TP 80

  • For severely contaminated fluids and faeces
  • 80 mm free ball passage
  • Ex-rated in accordance with ATEX as standard
  • Three-phase motor
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1
  • Can only be used for single pumping stations!

 

MTC 32

  • For severely contaminated fluids and faeces
  • External macerator
  • With and without Ex-rating in accordance with ATEX
  • For delivery heads up to 50 m
  • Compliant with (DIN) EN 12050-1

 

MTS 40

  • For severely contaminated fluids and faeces
  • Patented, internal macerator
  • Single-phase and three-phase AC versions available
  • Three-phase version with Ex-rating in accordance with ATEX
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

Special features / product benefits

Pumping of fluids that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level:

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

Wilo-DrainLift XL
DrainLift XL

Design

Sewage lifting unit as double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit that has the same performance capacity and switches on automatically when needed (DIN EN 12050-1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Power consumption P1 from 3 to 5.3 kW, depending on type
  • Cable length from system to switchgear 4 m / plug cable 1.5 m
  • Operating mode S1 / S3 ‐ 60%
  • Fluid temperature max. 40 °C, for short periods up to 60 °C
  • Ambient temperature max. 40 °C
  • Free ball passage 40 mm
  • Pressure port DN 80
  • Inlet connection DN 100 / DN 150
  • Ventilation connection DN 70
  • Min. suction head (installation level to middle of inlet) 700 mm
  • Protection class (without switchgear) IP 67
  • Gross tank volume 380 l
  • Switching volume 260 l
Wilo-DrainLift XXL
DrainLift XXL

Design

Sewage lifting unit as double-pump system with two separate dry-mounted pumps

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through sand catchers.

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Power consumption P1 from 2.3 to 10.0 kW, depending on type
  • Cable length from system to switchgear 10 m
  • Operating mode S1, S3
  • Fluid temperature max. 40 °C, for short periods up to 65 °C
  • Ambient temperature max. 40 °C
  • Free ball passage 78 mm to 95 mm, depending on type
  • Pressure port DN 80 or DN 100, depending on type
  • Inlet connection 3 x DN 100/150, 1 x DN 100
  • Ventilation connection DN 70 mm
  • Min. suction head (installation level to middle of inlet) 700 mm
  • Protection class (without switchgear) IP 68
  • Gross tank volume 400/800 l
  • Switching volume 200/400 l
Wilo-EMU FA...RF
EMU FA...RF

Design

Submersible sewage pump made of cast stainless steel without cooling system for continuous duty in stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Protection class: IP 68
  • Max. fluid temperature: 3 ‐ 40 °C, higher temperatures on request
  • Sealing: With two mechanical seals or one block seal cartridge, depending on the motor
  • Free ball passage: 35 - 45 mm.
  • Permanently lubricated roller bearings
  • Max. immersion depth: 20 m
Wilo-Rexa CUT
Rexa CUT

Design

Submersible sewage pump with macerator for intermittent duty and continuous duty, for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Non-immersed operating mode: S2-15 min/S2-30 min; S3 10%/S3 25% (motor-dependent)
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3…40 °C, max. 60 °C for 3 min
  • Max. immersion depth: 20 m
  • Cable length: 10 m
Wilo-RexaLift FIT L
RexaLift FIT L

Design

Sewage lifting unit as single pump system or double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit (RexaLift FIT L2) that has the same performance capacity and switches on automatically when needed (DIN EN 12050-1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Power consumption P1: 2.3 … 3.9 kW
  • Cable length from system to switchgear/plug: 4/1.5 m
  • Operating mode: S3-10%, 120 s
  • Fluid temperature: 3 °C … 40 °C, for short periods: 60 °C for max. 3 min.
  • Ambient temperature: 3 °C … 40 °C
  • Gross tank volume:
    • Single-pump system: 115 l
    • Double-pump system: 140 l

  • Switching volume:
    • Single-pump system: 35 l
    • Double-pump system: 50 l

  • discharge port: DN 80
  • Inlet connections: DN 50/DN 100/DN 150
  • Ventilation connection: DN 70
  • Free ball passage: 40 mm
  • Min. suction head (installation level to middle of inlet): 180 mm
  • Lifting unit protection class: IP67
  • Switchgear protection class: IP54
Wilo-Drain LP
Drain LP

Design

Self-priming drainage pump with standard motor for dry well installation

Application

Pumping of wastewater for

  • Ponds
  • Sprinkling / spraying of gardens and green areas
  • Mobile drainage

Special features / product benefits

Pumping of

  • Wastewater
  • Process water

Technical data

  • Mains connection: 1~230 V, 50 Hz
  • Protection class: 44
  • Fluid temperature: 3 ‐ 35 °C
  • Free ball passage: 5 mm
  • Connection: Rp 1½
  • Max. suction head: 6 m
Wilo-Drain MTC
Drain MTC

Design

Submersible sewage pump with external macerator for continuous duty for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz (only MTC 40) and 3~400 V, 50 Hz
  • Submerged operating mode: S1
  • Non-immersed operating mode: S2‑15 min or S3 30%
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3…40 °C (MTC 40: 3…35 °C)
  • Max. submersion depth: 10 m or 20 m
  • Cable length: 10 m
Wilo-Drain MTS
Drain MTS

Design

Submersible sewage pump with internal macerator for intermittent operation for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Submerged operating mode: S1
  • Non-immersed operating mode: S2-8 min; S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3…40 °C
  • Max. submersion depth: 10 m
  • Cable length: 10 m
Wilo-Drain STS 40
Drain STS 40

Design

Submersible sewage pump for intermittent operation for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1 or S3 25%
  • Protection class: IP 68
  • Insulation class: B
  • Thermal winding monitoring
  • Max. fluid temperature: 3 ‐ 35 °C
  • Cable length: 10 m
  • Free ball passage: 40 mm
  • Max. immersion depth: 5 m
Wilo-Drain TC 40
Drain TC 40

Design

Submersible sewage pump for intermittent operation for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz
  • Immersed operating mode: S1 or S3 25%
  • Surfaced operating mode: S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Thermal winding monitoring
  • Max. fluid temperature: 3 ‐ 40 °C
  • Cable length: 5 m
  • Free ball passage: 40 mm
  • Max. immersion depth: 5 m
Wilo-Drain TM/TMW/TMR 32
Drain TM/TMW/TMR 32

Design

Submersible drainage pump

Application

  • For pumping clear or slightly muddy water

    • From tanks, sumps or pits
    • For overflows and flooding
    • For draining basement stairways and basement areas

 

TMR

The TMR is suited for lowering the water level to a remaining level of 2 mm.

TMW

The service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by settling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours.

Wilo-Drain TMW 32 has a turbulator that prevents the build-up of sediment, expelling it together with the fluid. This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occupational safety hygiene regulations during cleaning of the pump sump are minimized.

Special features / product benefits

Pumping of

  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection 1~230 V, 50 Hz
  • Protection class: IP 68
  • Submersion depth max. 3 m
  • Fluid temperature 3 ‐ 35 °C, max. 90 °C for short periods up to 3 min.
  • Cable length 3 to 10 m, depending on type
  • Free ball passage 10 mm (TMR: 2 mm)
  • Pressure port Rp 1 ¼
Wilo-Drain TMT/TMC
Drain TMT/TMC

Design

Submersible drainage pump

Application

For industrial use, e.g. for condensate, hot water and aggressive fluids.

Special features / product benefits

Pumping of

  • Wastewater
  • Industrial wastewater with a maximum fluid temperature of 95 °C.

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Protection class: IP 68
  • Max. immersion depth: TMT 32: 7 m; TMC 32: 5 m; TMC 40: 5 m
  • Fluid temperature: immersed = 3 - 95 °C
  • Cable length: 10 m
  • Free ball passage: 9 mm
  • Pressure port: TMT 32…: G 1¼; TMC 32…: Rp 1¼; TMC 40: Rp 1½
Wilo-Drain TP 50/TP 65
Drain TP 50/TP 65

Design

Submersible sewage pump for continuous duty for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Non-immersed operating mode: S2-8 min, S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Thermal winding monitoring
  • Max. fluid temperature: 3 ‐ 35°C
  • Cable length: 10 m
  • Free ball passage: 44 mm
  • Max. immersion depth: 10 m
Wilo-Drain TP 80/TP 100
Drain TP 80/TP 100

Design

Submersible sewage pump for continuous duty for stationary and portable wet well installation, as well as stationary dry well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed and non-immersed operating modes: S1
  • Protection class: IP 68
  • Insulation class: F
  • Max. fluid temperature: 3 ‐ 40°C
  • Free ball passage: 80 or 95 mm
  • Max. immersion depth: 20 m
Wilo-Drain TS 40-65
Drain TS 40-65

Design

Submersible drainage pump

Application

Pumping of

  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Protection class: IP 68
  • Max. immersion depth:TS 40 = 5 m; TS 50/TS 65 = 10 m
  • Fluid temperature: 3 ‐ 35 °C
  • Cable length: 10 m
  • Free ball passage: 10 mm
  • Pressure port: TS 40 = Rp 1, TS 50 = Rp 1¼, TS 65 = Rp 2½
Wilo-Drain TS/TSW 32
Drain TS/TSW 32

Design

Submersible drainage pump

Application

  • For pumping clear or slightly muddy water

    • From tanks, sumps or pits
    • For overflows and flooding
    • For draining basement stairways and basement areas

  • From domestic areas (washing machine water, soapsuds)
  • From small fountains, waterworks or streams

 

TSW

The service life of submersible pumps, which are used in pump sumps and through which washing machine water, soapy water from basins and showers, or other mixtures flow, is considerably reduced by settling sediment. Such sediment can form deposits in the pump sump, resulting in the accumulation of mud and odours.

Wilo-Drain TSW 32 has a turbulator that prevents the build-up of sediment, expelling it together with the fluid. This reduces costs and the time needed for regular cleaning of the sump. In addition, problems associated with mud removal and the observance of occupational safety hygiene regulations during cleaning of the pump sump are minimised.

Special features / product benefits

Pumping of

  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection 1~230 V, 50 Hz
  • Protection class IP 68
  • Max. immersion depth 10 m
  • Fluid temperature 3 - 35 °C, for short periods up to 3 min. max. 90 °C
  • Cable length 10 m
  • Free ball passage 10 mm
  • Rp 1 ¼ pressure port, hose connection Ø 32 mm, R1
Wilo-DrainLift Box
DrainLift Box

Design

Small sewage lifting unit for concealed floor installation

Application

For concealed floor installation, can be used to drain

  • Rooms subject to possible flooding
  • Garage entrances
  • Basement stairways
  • Showers, washbasins, washing machines, dishwashers

Special features / product benefits

Pumping of pre-cleaned sewage without faeces (according to DIN EN 12050-2) that cannot be piped to the sewer system through the use of natural falls.

Technical data

  • Mains connection 1~230 V, 50 Hz
  • Mains connection cable 10 m (5 m with 40/10), with shock-proof plug
  • Operating mode S3 -25%
  • Fluid temperature max. 35 °C, with 32/8 and 32/11 for short periods (3 min) 90 °C
  • Pressure port Ø 40 mm
  • Inlet connection 100 mm
  • Ventilation connection 100 mm
  • Protection class IP 67
  • Gross tank volume 85 l
  • Switching volume 22 l, 30 l with 40/10
Wilo-DrainLift M
DrainLift M

Design

Sewage lifting unit as single pump system or double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit that has the same performance capacity and switches on automatically when needed (DIN EN 12050‐1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Power consumption P1 = 1.3 kW
  • Cable length from system to switchgear 4 m / plug cable 1.5 m
  • Operating mode S3-15%, 80 sec
  • Fluid temperature max. 40 °C, for short periods (3 min.) 60 °C
  • Max. ambient temperature of 40 °C
  • Free ball passage 45 mm
  • Pressure port DN 80
  • Inlet connection DN 40 / DN 100 / DN 150
  • Ventilation connection DN 70
  • Min. suction head (installation level to middle of inlet) 180 mm
  • Protection class (without switchgear) IP 67
  • Gross tank volume 62 l to 115 l, depending on type
  • Switching volume 24 l to 40 l, depending on type
Wilo-DrainLift S
DrainLift S

Design

Compact sewage lifting unit as single pump system

Application

Complete sewage lifting unit ready for connection in accordance with DIN EN 12050-1.

For the pumping of raw sewage that cannot be piped to the sewer system through the use of natural inclines. Wilo-DrainLift S meets the requirements of DIN EN 12050-1 and DIN EN 12056. Minimum dimensions, combined with space-optimised installation area enable a wide range of different application options for:

  • Retrofitting installation of showers, toilets, saunas, etc.
  • Installation of toilets in basement flats
  • Expansion/renovation of flats and buildings
  • Innovative combination of different installation options for sewage lifting units in a single system, e.g.:

    • Direct toilet connection
    • Drainage of individual rooms
    • Front wall installation/recessed wall installation

Can be used in the following installation types:

As conventional sewage lifting unit for connection of a wall-mounted or stand-alone toilet or for complete room drainage. Due to compact design, system requires only minimum space.
In conjunction with front wall installation/recessed wall installation, used as sewage lifting unit, integrated into commercially available front wall installation systems, in recessed wall installation as well as in pedestal profiles.

Note:

It must be possible to both install and remove the system after laying tiles. Observe installation instructions and accessories.

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Power consumption P1 from 1.1 to 1.25 kW, depending on type
  • Cable length from system to switchgear/plug 4 m
  • Operating mode S3-15%, 120 sec
  • Fluid temperature max. 35 °C, for short periods up to 60 °C
  • Max. ambient temperature of 40 °C
  • Free ball passage 40 mm
  • Pressure port DN 80
  • Inlet connection DN 40 / DN 100
  • Ventilation connection DN 70
  • Min. suction head (installation level to middle of inlet) 180 mm
  • Protection class (without switchgear) IP 67
  • Gross tank volume 45 l
Wilo-DrainLift WS 40 Basic
DrainLift WS 40 Basic

Design

Pump chamber made of plastic with integrated pump as concealed pumping station or floor-mounted lifting unit

Application

Wilo-DrainLift WS 40 Basic is an automatically operating wastewater lifting unit in accordance with EN 12050-2 for backup-free drainage of sewage that does not contain faeces and that originates from building discharge points below the backflow level. The system can be installed in buildings as well as outside buildings in the same way as a plastic sump in the ground. The system is ideally suited for applications that involve seasonal wastewater (such as at camping sites, weekend homes, etc.) or in regions where the ground does not freeze to very deep levels.

Built-in pump

TC 40

For severely contaminated fluids; 40 mm free ball passage

Special features / product benefits

Pumping of pre-cleaned sewage without faeces that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level.

Technical data

Wilo-DrainLift WS 40-50
DrainLift WS 40-50

Design

Pump chamber made of plastic as concealed pumping station or floor-mounted lifting unit

Application

Wilo-DrainLift WS 40-50 is an automatically operating sewage lifting unit in accordance with EN 12050 for backup-free drainage of sewage that either contains faeces or contains no faeces (depending on the type) and that originates from building discharge points below the backflow level.

The system can be installed in buildings as well as outside buildings in the same way as a plastic sump in the ground. The system is ideally suited for applications that involve seasonal wastewater (such as at camping sites, weekend homes, etc.), for use in regions where the earth does not freeze to very deep levels or also for use with pressure drainage.

When the system is used as a macerator lifting unit in a building, small pipeline diameters DN 40 and larger can be used on the pressure side in conformity with the relevant standard (in accordance with DIN EN 12050‐1). This enables flexible and low-cost overall installation.

Pumps that can be used

TP 50/TP 65

  • For severely contaminated fluids without faeces
  • 44 mm free ball passage
  • Ex-rated in accordance with ATEX (TP 65, depending on type)
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

 

MTS 40

  • For severely contaminated fluids and faeces
  • Patented, internal macerator
  • Single-phase and three-phase AC versions available
  • Three-phase version with Ex-rating in accordance with ATEX
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

Special features / product benefits

Pumping of fluids that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level:

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

Wilo-DrainLift WS 900/1100
DrainLift WS 900/1100

Design

Plastic pump chamber for insertion into the ground

Application

The Wilo-DrainLift WS 900/1100 is a single/double pump sump for pumping wastewater and sewage in building services out of rooms and from areas underneath the backflow level (EN 752). Suitable as a ready for connection pumps station for pressure drainage and as a pumping station for dewatering. The WS 900/1100 is installed in the ground outside the building. A time-saving, easy-to-install, low-cost solution for all consultants and building contractors.

Pump types that can be used

TS 40

  • For lightly contaminated fluids without faeces
  • 10 mm free ball passage
  • Not Ex-rated
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable

 

TP 50/TP 65

  • For severely contaminated fluids without faeces
  • 44 mm free ball passage
  • Ex-rated in accordance with ATEX (TP 65, depending on type)
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

Rexa FIT V05/V06

  • For severely contaminated fluids and faeces
  • 50 or 65 mm free ball passage
  • Not Ex-rated
  • Single-phase and three-phase AC versions available
  • Version with attached float switch available
  • Detachable connecting cable
  • Compliant with EN 12050-1

Rexa PRO V05/V06

  • For severely contaminated fluids and faeces
  • 50 or 65 mm free ball passage
  • Ex-rated in accordance with ATEX as standard
  • Single-phase and three-phase AC versions available
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

TP 80

  • For severely contaminated fluids and faeces
  • 80 mm free ball passage
  • Ex-rated in accordance with ATEX as standard
  • Three-phase motor
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1
  • Can only be used for single pumping stations!

 

MTC 32

  • For severely contaminated fluids and faeces
  • External macerator
  • With and without Ex-rating in accordance with ATEX
  • For delivery heads up to 50 m
  • Compliant with (DIN) EN 12050-1

 

MTS 40

  • For severely contaminated fluids and faeces
  • Patented, internal macerator
  • Single-phase and three-phase AC versions available
  • Three-phase version with Ex-rating in accordance with ATEX
  • Detachable connecting cable
  • Compliant with (DIN) EN 12050-1

Special features / product benefits

Pumping of fluids that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level:

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

Wilo-DrainLift XL
DrainLift XL

Design

Sewage lifting unit as double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit that has the same performance capacity and switches on automatically when needed (DIN EN 12050-1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Power consumption P1 from 3 to 5.3 kW, depending on type
  • Cable length from system to switchgear 4 m / plug cable 1.5 m
  • Operating mode S1 / S3 ‐ 60%
  • Fluid temperature max. 40 °C, for short periods up to 60 °C
  • Ambient temperature max. 40 °C
  • Free ball passage 40 mm
  • Pressure port DN 80
  • Inlet connection DN 100 / DN 150
  • Ventilation connection DN 70
  • Min. suction head (installation level to middle of inlet) 700 mm
  • Protection class (without switchgear) IP 67
  • Gross tank volume 380 l
  • Switching volume 260 l
Wilo-DrainLift XXL
DrainLift XXL

Design

Sewage lifting unit as double-pump system with two separate dry-mounted pumps

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through sand catchers.

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection 3~400 V, 50 Hz
  • Power consumption P1 from 2.3 to 10.0 kW, depending on type
  • Cable length from system to switchgear 10 m
  • Operating mode S1, S3
  • Fluid temperature max. 40 °C, for short periods up to 65 °C
  • Ambient temperature max. 40 °C
  • Free ball passage 78 mm to 95 mm, depending on type
  • Pressure port DN 80 or DN 100, depending on type
  • Inlet connection 3 x DN 100/150, 1 x DN 100
  • Ventilation connection DN 70 mm
  • Min. suction head (installation level to middle of inlet) 700 mm
  • Protection class (without switchgear) IP 68
  • Gross tank volume 400/800 l
  • Switching volume 200/400 l
Wilo-EMU FA (standard variant)
EMU FA (standard variant)

Design

Submersible sewage pump without cooling system for continuous duty for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Surfaced operating mode: S1, S2-15 or S2-30 (depending on type)
  • Thermal motor monitoring
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3 ‐ 40 °C
  • Cable length: 10 m
  • Free ball passage from 45 mm to 100 mm
  • Permanently lubricated roller bearings
  • Max. immersion depth: 20 m
Wilo-EMU FA…T
EMU FA…T

Design

Submersible sewage pump with and without active cooling system for pumping untreated sewage for continuous duty in the stationary and portable wet well installation, as well as stationary dry well installation.

Application

Pumping of

  • Untreated sewage with faeces and long-fibre components
  • Sewage containing faeces
  • Process water

Special features / product benefits

Pumping of

  • Untreated sewage with faeces and long-fibre components
  • Sewage containing faeces
  • Process water

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Surfaced operating mode with self-cooling motor: S1
  • Non-immersed operating mode with glanded motor: S2-15 min (depending on type)
  • Protection class: IP 68
  • Fluid temperature: 3 ‐ 40°C; higher temperatures on request
  • Sealing: With rotary shaft seal and mechanical seal, two mechanical seals or one block seal cartridge, depending on the motor
  • Free passage: 78x105 - 150x150 mm.
  • Permanently lubricated roller bearings
  • Max. immersion depth: 20 m
Wilo-EMU FA...RF
EMU FA...RF

Design

Submersible sewage pump made of cast stainless steel without cooling system for continuous duty in stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Process water
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Protection class: IP 68
  • Max. fluid temperature: 3 ‐ 40 °C, higher temperatures on request
  • Sealing: With two mechanical seals or one block seal cartridge, depending on the motor
  • Free ball passage: 35 - 45 mm.
  • Permanently lubricated roller bearings
  • Max. immersion depth: 20 m
Wilo-EMU FA...WR
EMU FA...WR

Design

Submersible sewage pump with mechanical stirring apparatus for continuous duty for stationary wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Surfaced operating mode with self-cooling motor: S1
  • Protection class: IP 68
  • Max. fluid temperature: 3 ‐ 40 °C, higher temperatures on request
  • Sealing: With rotary shaft seal and mechanical seal, two mechanical seals or one block seal cartridge, depending on the motor
  • Free ball passage: 23 - 58 mm.
  • Permanently lubricated roller bearings
  • Max. immersion depth: 20 m
Wilo-HiDrainlift 3
HiDrainlift 3

Design

Small sewage lifting unit for floor-mounted installation

Application

Pumping of pre-cleaned sewage without faeces (according to DIN EN 12050-2) that cannot be piped to the sewer system through the use of natural falls.

Special features / product benefits

Pumping of pre-cleaned sewage without faeces (according to DIN EN 12050-2) that cannot be piped to the sewer system through the use of natural falls.

Technical data

  • Netzanschluss 1~230 V, 50 Hz
  • Netzanschlusskabel 1,5 m, mit Schuko-Stecker (außer HiDrainlift 3-24)
  • Fördermedientemperatur max. 35 °C (bis zu 60/ 75 °C im Kurzzeitbetrieb für 5 Minuten, modellabhängig)
  • Druckanschluss DN 32
  • Zulaufanschluss DN 40
  • Schutzart IP 44
  • Behälter-Bruttovolumen 3,9 l / 16 l / 15,5 l
  • Schaltvolumen 1,7 l / 2 l / 2 l
Wilo-HiSewlift 3
HiSewlift 3

Design

Small sewage lifting unit with macerator

Application

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be piped to the sewer system through the use of natural falls.

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be piped to the sewer system through the use of natural falls.

Technical data

  • Netzanschluss 1~230 V, 50 Hz
  • Netzanschlusskabel 1,5 m, mit Schuko-Stecker
  • Fördermedientemperatur max. 35 °C
  • Druckanschluss DN 32
  • Zulaufanschluss DN 40
  • Schutzart IP 44
  • Behälter-Bruttovolumen 14,4 l / 17,4 l / 17,4 l
  • Schaltvolumen 1 l
Wilo-Rexa CUT
Rexa CUT

Design

Submersible sewage pump with macerator for intermittent duty and continuous duty, for stationary and portable wet well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Non-immersed operating mode: S2-15 min/S2-30 min; S3 10%/S3 25% (motor-dependent)
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3…40 °C, max. 60 °C for 3 min
  • Max. immersion depth: 20 m
  • Cable length: 10 m
Wilo-Rexa FIT
Rexa FIT

Design

Submersible sewage pump for intermittent operation for stationary and portable wet well installation, as well as stationary dry well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Non-immersed operating mode: S2-15 min; S3 10%
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3 - 40°C, max. 60°C for 3 min
  • Free passage: 50 / 65 / 80 mm
  • Max. immersion depth: 20 m
  • Cable length: 10 m
Wilo-Rexa PRO
Rexa PRO

Design

Submersible sewage pump for continuous duty for stationary and portable wet well installation, as well as stationary dry well installation.

Application

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Special features / product benefits

Pumping of

  • Sewage containing faeces
  • Pre-cleaned sewage without faeces and long-fibre components
  • Wastewater

Technical data

  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Immersed operating mode: S1
  • Non-immersed operating mode: S2‑30 min; S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Fluid temperature: 3 - 40°C, max. 60°C for 3 min
  • Free passage: 50 / 65 / 80 mm
  • Max. immersion depth: 20 m
  • Cable length: 10 m
Wilo-RexaLift FIT L
RexaLift FIT L

Design

Sewage lifting unit as single pump system or double-pump system

Application

Sewage lifting unit for drainage of residential housing and commercial buildings (e.g. restaurants, department stores, etc.). Raw sewage that cannot be piped to the sewer system through the use of natural inclines and sewage from toilet systems below the backflow level are to be piped to the public sewer system by means of an automatic lifting unit in accordance with DIN EN 12056/ DIN 1986‐100. Sewage containing mineral oils or explosive admixtures must be guided through oil precipitators and/or petrol precipitators; those containing fatty substances must go through grease traps and those with sand through grit chambers. In cases where the flow to the lifting unit must not be interrupted during normal operation, one lifting unit must be equipped with a second pumping unit (RexaLift FIT L2) that has the same performance capacity and switches on automatically when needed (DIN EN 12050-1 A1).

Special features / product benefits

Pumping of sewage containing faeces (according to DIN EN 12050-1) that cannot be returned to the sewer system using natural falls, and for the backflow resistant drainage of discharge points below the backflow level (according to DIN EN 12056-1).

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Power consumption P1: 2.3 … 3.9 kW
  • Cable length from system to switchgear/plug: 4/1.5 m
  • Operating mode: S3-10%, 120 s
  • Fluid temperature: 3 °C … 40 °C, for short periods: 60 °C for max. 3 min.
  • Ambient temperature: 3 °C … 40 °C
  • Gross tank volume:
    • Single-pump system: 115 l
    • Double-pump system: 140 l

  • Switching volume:
    • Single-pump system: 35 l
    • Double-pump system: 50 l

  • discharge port: DN 80
  • Inlet connections: DN 50/DN 100/DN 150
  • Ventilation connection: DN 70
  • Free ball passage: 40 mm
  • Min. suction head (installation level to middle of inlet): 180 mm
  • Lifting unit protection class: IP67
  • Switchgear protection class: IP54
Wilo-Sevio ACT
Sevio ACT

Design

Solids diffuser

Application

Gentle mixing process of biomass particles in the pumped fluid

Special features / product benefits

Gentle mixing process of biomass particles in the pumped fluid

Technical data

  • Volume flow rate: 3300…4000 m³/h
  • Max. basin depth: 3...8 m
  • Layer thickness of biomass particles: 1.6...5.5 m
  • Percent by volume of biomass particles: 40…70 %
  • Mains connection: 3~400 V, 50 Hz,
  • Immersed operating mode: S1
  • Protection class: IP 68
  • Max. fluid temperature: 40 °C
Wilo-Sevio AIR
Sevio AIR

Design

Aeration system with air inlet vales, stripe or disc aerators

Application

For large to fine-bubble aeration of aqueous media such as water, sewage or sludge, for the purpose of supplying oxygen and intermixing.

Special features / product benefits

For large to fine-bubble aeration of aqueous media such as water, sewage or sludge, for the purpose of supplying oxygen and intermixing.

Technical data

Disc aerator

  • Outer diameter: 280 mm
  • Diaphragm diameter: 237 mm
  • Diaphragm surface area: 0.044 m²
  • Oxygen utilisation: 6.5…8.5 %/m
  • Size of the air bubbles: 1-3 mm
  • Pressure loss: 22…43 mbar
  • Connection size: 90 mm for plastic pipework, 88.9 mm for stainless steel pipework
  • Max. air temperature in the system/disc aerator: 100 °C

Loading range*

  • Air volume range: 1-8 Nm³/h
  • Min. loading: 1.5 Nm³/h
  • Standard loading: 4.0 Nm³/h
  • Max. loading: 6.0 Nm³/h
  • A loading of 7.5 Nm³/h is possible for short periods (max. 15 minutes)

*The values for loading apply under standard conditions: 0 °C and 1013 hPa.

Wilo-Sevio MIX DM
Sevio MIX DM

Design

Submersible mixer for MUD applications

Application

For pumping drilling mud in offshore and on-shore installations

Special features / product benefits

For pumping drilling mud in offshore and on-shore installations

Technical data

  • Mains connection: 3~400 V, 50 Hz,
  • Immersed operating mode: S1
  • Protection class: IP 68
  • Max. fluid temperature: 90 °C
  • Gear: Single-stage planetary gear
  • Max. immersion depth: 20 m
Wilo-Sevio MIX/FLOW BG
Sevio MIX/FLOW BG

Design

Submersible mixer for biogas applications with 1- and 2-stage planetary gear

Application

Submersible mixers for use in biogas plants for mixing substrates in fermenters and secondary fermentation tanks.

Special features / product benefits

Submersible mixers for use in biogas plants for mixing substrates in fermenters and secondary fermentation tanks.

Technical data

  • Mains connection: 3~400 V, 50 Hz,
  • Submerged operating mode: S1
  • Protection class: IP 68
  • Max. fluid temperature: 60 °C
  • Gear: 1-stage (Sevio MIX) or 2-stage (Sevio FLOW) planetary gear
  • Max. submersion depth: 20 m
Share with others

How to contact us

We are glad to help you

If you have any questions, please contact us.

Working hours: Sunday till Thursday from 8:30 am to 5:30 pm.

Or send us your request: info@wilo.ae

T +97148809177

F +97148809188

Wastewater collection and transport

Pioneering for You